RITTER · Made in Germany
BG 100 · Data Sheet

Legend

Performance Data

Minimum flow Qmin 1,000 ltr/h
Standard flow Qstandard 95,000 ltr/h
Maximum flow Qmax 160,000 ltr/h
Measurement accuracy (2) 2 %
Measuring cavity capacity 120 ltr/U
Temperature range 5 to +40 °C
Maximum gas inlet pressure 500 mbar
Minimum differential pressure (1) 1 mbar
Minimum dial division 0.4 ltr
Indication dial plate 100 ltr
Maximum indication value (3) 999,999,990 ltr
Weight 130 kg
  • (1) Differential pressure (= pressure loss) gas inlet gas outlet
  • (2) Across the measuring range in relation to the calibration value at nominal flow
  • (3) Standard Totalizing Roller Counter

No reverse flow direction possible!

Models (materials)

  • Casing: zinc-coated steel sheet (soldered) with outside also lacquered
  • Measuring unit: Tinplate
  • Bellows (within measuring unit): textile-reinforced nitrile rubber (Perbunan®)
  • Rod linkage: Polyamide
  • Slide gate: Bakelite

Standard Equipment

  • 8-digit Totalizing Roller Counter
  • Flanschanschluss DN 100, gemäß DIN 2642-PN10
  • Large, One-needle Dial
  • Magnet-Kupplung (zwischen Messwerk und Zählwerk)
  • Twin-Chamber Measuring Unit

Built-in Options

V 3.0 / Rev. 2023-03-09 / Subject to alterations.