Legend

Performance Data

Minimum flow Qmin 60 ltr/h
Standard flow Qstandard 5,000 ltr/h
Maximum flow Qmax 10,000 ltr/h
Measurement accuracy (2) 2 %
Measuring cavity capacity 3.5 ltr/U
Temperature range 5 to +40 °C
Maximum gas inlet pressure 300 mbar
Minimum differential pressure (1) 1 mbar
Minimum dial division 0.2 ltr
Indication dial plate 20 ltr
Maximum indication value (3) 99,999,999 ltr
Weight 6.4 kg
  • (1) Differential pressure (= pressure loss) gas inlet gas outlet
  • (2) Across the measuring range in relation to the calibration value at nominal flow
  • (3) Standard Totalizing Roller Counter

No reverse flow direction possible!

Models (materials)

  • Casing: zinc-coated steel sheet (soldered) with outside also lacquered
  • Measuring unit: Tinplate
  • Bellows (within measuring unit): textile-reinforced nitrile rubber (Perbunan®)
  • Rod linkage: Polyamide
  • Slide gate: Bakelite

Standard Equipment

  • 8-digit Totalizing Roller Counter
  • Gewindeanschluss 1-1/4“ (G 1-1/4 A, DIN ISO 228)
  • Large, One-needle Dial
  • Magnet-Kupplung (zwischen Messwerk und Zählwerk)
  • Twin-Chamber Measuring Unit

Built-in Options