RITTER · Made in Germany
TG 20 Stainless steel 6 bar · Data Sheet

Legend

Performance Data

Minimum flow Qmin 40 ltr/h
Standard flow Qstandard 3,200 ltr/h
Maximum flow Qmax 4,000 ltr/h
Measurement accuracy at standard flow 0.2 %
Measurement accuracy across measuring range 0.5 %
Measuring drum volume 20 ltr/U
Packing liquid quantity, approx 29 ltr
Maximum gas inlet pressure 6 bar
Minimum differential pressure (1) 0.1 mbar
Minimum dial division 0.2 ltr
Maximum indication value (2) 999,999,990 ltr
Connection gas in/outlet
Inside-Ø 18 mm
Outside-Ø 26 mm
(1) Differential pressure (= pressure loss) gas inlet gas outlet
(2) Standard Totalizing Roller Counter

Models (materials)

Model Casing Measuring drum Width Height Depth Weight
(without packing liquid)
Max. constant
use temperature
1 Stainless Steel PVC-grey 540 mm 610 mm 700 mm 93.9 kg 40 °C
2 Stainless Steel PE-el 540 mm 610 mm 700 mm 93.5 kg 60 °C
3 Stainless Steel PP-grey 540 mm 610 mm 700 mm 93.5 kg 60 °C
4 Stainless Steel PVDF 540 mm 610 mm 700 mm 94.7 kg 60 °C

Caution

Before and after measurements with oxygen purge the meter with an inert gas to avoid the danger of explosion!

For chemical resistance properties please contact your RITTER distribution partner!

Standard Equipment

  • 8-digit Totalizing Roller Counter
  • Bubble level for levelling
  • Level and Levelling Feet
  • Multi-Chamber Measuring Drum
  • Supports for Thermometer and Manometer
  • Viton sealing