RITTER · Made in Germany
TG 10 Plastic · Data Sheet

Technical Drawing

Legend

Performance Data

Minimum flow Qmin 20 ltr/h
Standard flow Qstandard 1,000 ltr/h
Maximum flow Qmax 1,200 ltr/h
Measurement accuracy at standard flow ± 0.2 %
Measurement accuracy across measuring range ± 0.5 %
Measuring drum volume 10 ltr/U
Packing liquid quantity, approx 15.5 ltr
Maximum gas inlet pressure 50 mbar
Minimum differential pressure (1) 0.1 mbar
Minimum dial division 0.1 ltr
Maximum indication value (2) 99,999,999 ltr
Connection gas in/outlet
Inside-Ø 19 mm
Outside-Ø 25 mm

(1) Differential pressure (= pressure loss) gas inlet gas outlet
(2) Standard Totalizing Roller Counter

Models (materials)

Model Casing Measuring drum Width Height Depth Weight
(without packing liquid)
Max. constant
use temperature
5 PVC-transparent PVC-grey 410 mm 470 mm 560 mm 10.6 kg 40 °C
6 PP-grey PP-grey 410 mm 470 mm 560 mm 7.8 kg 80 °C
7 PVDF PVDF 410 mm 470 mm 560 mm 13.6 kg 80 °C
8 PE-el PE-el 410 mm 470 mm 560 mm 7.8 kg 60 °C

Caution

Before and after measurements with oxygen purge the meter with an inert gas to avoid the danger of explosion!

For chemical resistance properties please contact your RITTER distribution partner!

Standard Equipment

  • 8-digit Totalizing Roller Counter
  • Acoplamento magnético entre o tambor de medição e o contador: Invólucro absolutamente estanque a líquidos
  • Bubble level for levelling
  • Level and Levelling Feet
  • Multi-Chamber Measuring Drum
  • Supports for Thermometer and Manometer
  • Viton sealing

V 2.1 / Rev. 2023-03-09 / Subject to alterations.