RITTER · Made in Germany
TG 20 Plastic · Data Sheet

Technical Drawing

Legend

Performance Data

Minimum flow Qmin 40 ltr/h
Standard flow Qstandard 3,200 ltr/h
Maximum flow Qmax 4,000 ltr/h
Measurement accuracy at standard flow ± 0.2 %
Measurement accuracy across measuring range ± 0.5 %
Measuring drum volume 20 ltr/U
Packing liquid quantity, approx 28.5 ltr
Maximum gas inlet pressure 50 mbar
Minimum differential pressure (1) 0.1 mbar
Minimum dial division 0.2 ltr
Maximum indication value (2) 999,999,990 ltr
Connection gas in/outlet
Inside-Ø 19 mm
Outside-Ø 25 mm

(1) Differential pressure (= pressure loss) gas inlet gas outlet
(2) Standard Totalizing Roller Counter

Models (materials)

Model Casing Measuring drum Width Height Depth Weight
(without packing liquid)
Max. constant
use temperature
5 PVC-transparent PVC-grey 505 mm 545 mm 615 mm 18.0 kg 40 °C
6 PP-grey PP-grey 505 mm 545 mm 615 mm 13.4 kg 80 °C
7 PVDF PVDF 505 mm 545 mm 615 mm 23.2 kg 80 °C
8 PE-el PE-el 505 mm 545 mm 615 mm 13.4 kg 60 °C

Caution

Before and after measurements with oxygen purge the meter with an inert gas to avoid the danger of explosion!

For chemical resistance properties please contact your RITTER distribution partner!

Standard Equipment

  • 8-digit Totalizing Roller Counter
  • Acoplamento magnético entre o tambor de medição e o contador: Invólucro absolutamente estanque a líquidos
  • Bubble level for levelling
  • Level and Levelling Feet
  • Multi-Chamber Measuring Drum
  • Supports for Thermometer and Manometer
  • Viton sealing

V 2.1 / Rev. 2023-03-09 / Subject to alterations.