Performance Data

Minimum flow Qmin 40 ltr/h
Standard flow Qstandard 3,200 ltr/h
Maximum flow Qmax 4,000 ltr/h
Measurement accuracy at standard flow 0.2 %
Measurement accuracy across measuring range 0.5 %
Measuring drum volume 20 ltr/U
Packing liquid quantity, approx 30 ltr
Maximum gas inlet pressure (1) 500 mbar
Minimum differential pressure (2) 0.1 mbar
Minimum dial division 0.2 ltr
Maximum indication value (3) 999,999,990 ltr
Connection gas in/outlet
Inside-Ø 17.2 mm
Outside-Ø 26 mm
(1) Standard version: 500 mbar – special version also available for 1 bar
(2) Differential pressure (= pressure loss) gas inlet gas outlet
(3) Standard Totalizing Roller Counter

Models (materials)

Model Casing Measuring drum Width Height Depth Weight
(without packing liquid)
Max. constant
use temperature
1 Stainless Steel PVC-grey 484 mm 560 mm 610 mm 32.5 kg 40 °C
2 Stainless Steel PE-el 484 mm 560 mm 610 mm 32.1 kg 60 °C
3 Stainless Steel PP-grey 484 mm 560 mm 610 mm 32.1 kg 80 °C
4 Stainless Steel PVDF 484 mm 560 mm 610 mm 33.3 kg 80 °C

Caution

Before and after measurements with oxygen purge the meter with an inert gas to avoid the danger of explosion!

For chemical resistance properties please contact your RITTER distribution partner!

Standard Equipment

  • 8-digit Totalizing Roller Counter
  • Acoplamento magnético entre o tambor de medição e o contador: Invólucro absolutamente estanque a líquidos
  • Bubble level for levelling
  • Level and Levelling Feet
  • Multi-Chamber Measuring Drum
  • Supports for Thermometer and Manometer
  • Viton sealing