RITTER · Made in Germany
TG 25 Plastic · Data Sheet

Technical Drawing

Legend

Performance Data

Minimum flow Qmin 50 ltr/h
Standard flow Qstandard 5,000 ltr/h
Maximum flow Qmax 7,000 ltr/h
Measurement accuracy at standard flow ± 0.2 %
Measurement accuracy across measuring range ± 0.5 %
Measuring drum volume 25 ltr/U
Packing liquid quantity, approx 42 ltr
Maximum gas inlet pressure 50 mbar
Minimum differential pressure (1) 0.1 mbar
Minimum dial division 0.1 ltr
Maximum indication value (2) 999,999,990 ltr
Connection gas in/outlet
Inside-Ø 24 mm
Outside-Ø 32 mm

(1) Differential pressure (= pressure loss) gas inlet gas outlet
(2) Standard Totalizing Roller Counter

Models (materials)

Model Casing Measuring drum Width Height Depth Weight
(without packing liquid)
Max. constant
use temperature
5 PVC-transparent PVC-grey 550 mm 640 mm 665 mm 26.7 kg 40 °C
6 PP-grey PP-grey 550 mm 640 mm 665 mm 19.4 kg 80 °C
7 PVDF PVDF 550 mm 640 mm 665 mm 34.5 kg 80 °C
8 PE-el PE-el 550 mm 640 mm 665 mm 19.4 kg 60 °C

Caution

Before and after measurements with oxygen purge the meter with an inert gas to avoid the danger of explosion!

For chemical resistance properties please contact your RITTER distribution partner!

Standard Equipment

  • 8-digit Totalizing Roller Counter
  • Acoplamento magnético entre o tambor de medição e o contador: Invólucro absolutamente estanque a líquidos
  • Bubble level for levelling
  • Level and Levelling Feet
  • Multi-Chamber Measuring Drum
  • Supports for Thermometer and Manometer
  • Viton sealing

V 3.2 / Rev. 2023-03-09 / Subject to alterations.