Pulse Generator V2.0-Ex


Quick reference 50 pulses per revolution of measuring drumFor use with TG05 to TG50 and BG4 to BG100Uni-directionalApplicable for ex-proof areas (1) Application The Pulse Generator for RITTER Drum-type Gas Meters and Bellows-type Gas Meters is a rotary …

Quick reference 50 pulses per revolution of measuring drum For use with TG05 to TG50 and BG4 to BG100 Uni-directional Applicable for ex-proof areas (1) Application The Pulse Generator for RITTER Drum-type Gas Meters and Bellows-type Gas Meters is a rotary encoder for pulse output. It can be…

Ler maisPulse Generator V2.0-Ex

Pulse Generator V3.2-200 »Smart PG«


Quick reference 200 pulses per revolution of measuring drumFor use with TG05 to TG50 and BG4 to BG100Uni-directionalNot applicable for ex-proof areas Application The Pulse Generator for RITTER Drum-type Gas Meters and Bellows-type Gas Meters is a …

Quick reference 200 pulses per revolution of measuring drum For use with TG05 to TG50 and BG4 to BG100 Uni-directional Not applicable for ex-proof areas Application The Pulse Generator for RITTER Drum-type Gas Meters and Bellows-type Gas Meters is a rotary encoder for pulse output. It can…

Ler maisPulse Generator V3.2-200 »Smart PG«

Pulse Generator V3.2-50 »Smart PG«

  • 50 Impulse pro Umdrehung der Messtrommel
  • Für TG05 bis TG50 und BG4 bis BG100
  • Keine Drehrichtungserkennung
  • Nicht im Ex-Bereich einsetzbar

Kurzinformation Anwendung Mit dem Impulsgeber der RITTER Trommel-Gaszähler und Balgen-Gaszähler kann das gemessene Gasvolumen zur Fernübertragung und/oder Weiterverarbeitung (Berechnung des Volumenstromes, Datentransfer via RS232) zur elektronischen Digital-Anzeigeeinheit »EDU 32 FP« (optionales Zubehör) oder zu einer externen Datenerfassung (PC, Schreiber) übertragen werden. In…

Ler maisPulse Generator V3.2-50 »Smart PG«

Pulse Generator V4.01


Quick reference 2 x 200 pulses per revolution of measuring drumFor use with TG05 to TG50, not for BG types (because of pawl with BG types)Bi-directional (1)Not applicable for ex-proof areas Application The Pulse …

Quick reference 2 x 200 pulses per revolution of measuring drum For use with TG05 to TG50, not for BG types (because of pawl with BG types) Bi-directional (1) Not applicable for ex-proof areas Application The Pulse Generator for RITTER Drum-type Gas Meters is a rotary…

Ler maisPulse Generator V4.01

Pulse Generator V4.11

  • 500 Impulse pro Umdrehung der Messtrommel
  • Für TG05 bis TG50 und BG4 bis BG100
  • Keine Drehrichtungserkennung
  • Nicht im Ex-Bereich einsetzbar

Kurzinformation Anwendung Mit dem Impulsgeber der RITTER Trommel-Gaszähler und Balgen-Gaszähler kann das gemessene Gasvolumen zur Fernübertragung und/oder Weiterverarbeitung (Berechnung des Volumenstromes, Datentransfer via RS232) zur elektronischen Digital-Anzeigeeinheit »EDU 32 FP« (optionales Zubehör) oder zu einer externen Datenerfassung (PC, Schreiber) übertragen werden.…

Ler maisPulse Generator V4.11

Pulse Generator V6.0 (Reed Contact)


Application The Pulse Generator V6.0 (Reed Contact) for RITTER MilliGascounters is used to transfer the measured gas volume to an external measuring instrument (Computer, PC). To convert the signal for USB-output and …

Application The Pulse Generator V6.0 (Reed Contact) for RITTER MilliGascounters is used to transfer the measured gas volume to an external measuring instrument (Computer, PC). To convert the signal for USB-output and use in conjunction with Data Acquisition Software »Rigamo« the Signal Interface Module (»SIM«) (both…

Ler maisPulse Generator V6.0 (Reed Contact)