Balgen-Gaszähler BG 40

RITTER · Made in Germany
Balgen-Gaszähler BG 40 · Data Sheet

Legend

  1. Eingang (Gas)
  2. Ausgang (Gas)
  3. Abnehmbare Blendkappe
  4. Anschluss Impulsgeber (Sonderausführung)
  5. Rückstelltaste (Sonderausführung)

Performance Data

Minimum flow Qmin 400 ltr/h
Standard flow Qstandard 39.000 ltr/h
Maximum flow Qmax 65.000 ltr/h
Measurement accuracy (2) 2 %
Measuring cavity capacity 30 ltr/U
Temperature range 5 to +40 °C
Maximum gas inlet pressure 500 mbar
Minimum differential pressure (1) 1 mbar
Minimum dial division 0,4 ltr
Indication dial plate 100 ltr
Maximum indication value (3) 999.999.990 ltr
Weight 33 kg
  • (1) Differential pressure (= pressure loss) gas inlet gas outlet
  • (2) Across the measuring range in relation to the calibration value at nominal flow
  • (3) Standard Totalizing Roller Counter

No reverse flow direction possible!

Models (materials)

  • Casing: zinc-coated steel sheet (soldered) with outside also lacquered
  • Measuring unit: Tinplate
  • Bellows (within measuring unit): textile-reinforced nitrile rubber (Perbunan®)
  • Rod linkage: Polyamide
  • Slide gate: Bakelite

Standard Equipment

  • Doppelkammer-Messteil
  • Flanschanschluss DN 65 (DIN 2642-PN10)
  • Großes Ein-Zeiger-Zifferblatt
  • Magnet-Kupplung (zwischen Messwerk und Zählwerk)
  • Summierendes Rollenzählwerk (8-stellig)

Built-in Options

  • LCD-Anzeige , rückstellbar, 8-stellig (anstelle Rollenzählwerk, summierend)
  • Impulsgeber , Standard- oder Ex-Version (zum Anschluss an Digitalanzeige-Einheit/PC)

Accessories

V 3.0 / Rev. 2022-10-16 / Subject to alterations.