MultiGas Sensore infrarossi NDIR

  • Sensore NDIR = sensore ad infrarossi non dispersivo
  • Dotato di diodi emettitori di luce ad alte prestazioni (IR-LED) e di micro-radiatori termici

Panoramica

The RITTER MultiGas Sensors NDIR Module (non-dispersive IR sensor) has been specially developed for use in high-quality gas analysis. In the design phase special emphasis was placed on high stability and a low detection limit. These goals could be fully achieved by using high-performance light-emitting diodes (IR-LED) and thermal micro-radiators which were adapted to the requirements of gas detection. In the spectral range from 2 μm to 12 μm, carbon dioxide, carbon monoxide, hydrocarbons, water vapor and sulfur hexafluoride can be safely detected down to the ppm range with this innovative sensor platform.

The various photometric components such as detectors, emitters, measuring sample cell, etc. will be assembled user-specifically in a high-quality tabletop casing by RITTER.
RITTER MultiGas Sensorgehäuse

Applications

Characteristics and Benefits

  • Group of detectable gases:
  • Measurement technology: NDIR-Sensor (non-dispersive IR sensor)
  • Accuratezza di misurazione ±2% of Full Scale (F.S.)
  • No cross-sensitivity to H2
  • Operating temperature: 5 – 45 °C
  • Operating pressure: 800 – 1200 mbar (hPa) abs.
  • Flow rate range: 1 ltr/day – 100 ltr/h
  • Warm-up time: 2 min
  • Response time (t90): ≈ 3 sec
  • Interface USB, on request RS 232
  • Sensor cuvette: Aluminum, gold plated for sensor length 100 ≥ mm
  • Incl. temperature compensation
  • Incl. data acquisition software
  • In tabletop casing, overall dimensions W x H x L 171 x 85 x 246 mm, weight approx. 1,9 kg
  • Gas connection: PVDF screw-type tube connection for tube Øi 4 mm, Øa 6 mm
  • Power supply: 24 VDC (incl. power plug 100 – 240 VAC / 24 VDC)

Recalibration

  • Readjustment of the zero-point is recommended once a week.
  • Contamination of the measuring cuvette can lead to shifting of the end-point. Due to the integrated filter, re-adjustment of the end-point is generally not required – but can be performed once a year.
  • Additionally, cartridges filled with an inert and the respective test gas for recalibration of the zero and end-point can be provided.
  • Long-term drift is < 1% of Full Scale (F.S.) / 24 h.

Additional sensors / Sensor options

Sensore di pressione

  • Compensazione della pressione delle concentrazioni di gas misurate
  • Campo di misura:
    • Versione standard 800 - 1.200 mbar ass.
    • Versione resistente all'H2S 0,2 - 3,5 bar abs.
  • Precisione di misura ±1% dello span (fondo scala)
  • Risoluzione: <1 mbar (2 mbar per la versione resistente all'H2S)
  • Tempo di risposta (t90): 1 s
  • Incl. compensazione della temperatura
Leggi tutto Sensore di pressione